Product Description
Dual Supply for Hot and Cold Water Service
Operating static pressure: 20-125 PSI (138-862 kPa)
Minimum static pressure for mixing: 30 PSI (207 kPa)
Cold water inlet temperature range: 39-80ºF (4-27ºC)
Hot water inlet temperature range: 120-180ºF (49-82ºC)
Mixed water temperature range: 80-120ºF (27-49ºC)
Accurate within +/- 3ºF (1.7ºC)
Adjustable temperature control
Maximum pressure differential between hot and cold water supplies: 20%
Maximum temperature differential between hot and cold water supplies: 20ºF (9ºC)
Includes pre-assembled thermostatic mixing element and installation hardware
Installation should be in accordance with local plumbing codes.
ECAST® construction with equal to or less than 0.25% lead content by weighted average
Weight: 0.201lbs